NEW QUESTION 19
Your customer has a FlexPod implementation and wants to use life-cycle management to validate, monitor, and optimize the FlexPod infrastructure.
In this situation, which management tool should your customer use?

  • A. NetApp OnCommand Unified Manager
  • B. NetApp Converged System Advisor
  • C. Cisco UCS Director
  • D. Cisco UCS Manager

Answer: C

Explanation:
Cisco UCS Director can be an integral companion for FlexPod because it allows holistic management through centralized automation and orchestration from a single, unified view. When FlexPod and Cisco UCS Director are combined, IT can shift time and focus from managing infrastructure to delivering new service innovation. Used together, FlexPod and Cisco UCS Director deliver:

 

NEW QUESTION 20
A client has a requirement to set up a FlexPod Datacenter with the NetApp fabric MetroCluster architecture. You want to enable connectivity between the deployments.
In this design, which two components are required to accomplish this task? (Choose two.)

  • A. Cisco MDS 9300 switches
  • B. Cisco Nexus 9000 switches
  • C. Cisco Nexus 7000 switches
  • D. Cisco Nexus 3000 switches

Answer: B,C

 

NEW QUESTION 21
A customer is designing a FlexPod solution to use both NFS and iSCSI for connectivity, including traditional FC for legacy applications. The Cisco UCS Fabric Interconnects will be connected to both Nexus 9000 Series switches and FC switches.
Which UCS capability allows you to accomplish this task?

  • A. FC uplink ports
  • B. SAN pin groups
  • C. unified ports
  • D. VSANs

Answer: C

 

NEW QUESTION 22
A customer is designing a FlexPod solution with VMware 6.x in a SAN boot environment using FCoE. The customer has predetermined the WWPN values for the NetApp LIFs and the UCS vHBAs. The customer is now working on the design workflow for the SAN boot process.
In this scenario, which three FlexPod environment objects are required for SAN connectivity? (Choose three.)

  • A. initiator groups
  • B. UCS IQN pools
  • C. NetApp export policies
  • D. UCS boot policies
  • E. FC zones

Answer: B,C,D

 

NEW QUESTION 23
Which two NetApp storage controllers would be used in a valid FlexPod Datacenter configuration? (Choose two.)

  • A. NetApp EF570
  • B. NetApp FAS2700
  • C. NetApp AFF A700
  • D. NetApp E2800

Answer: B,C

 

NEW QUESTION 24
Two data centers are 75km apart. The customer wants to deploy a FlexPod solution in each data center to maintain high availability between the two sites with minimal possible data loss.
In this scenario, which technology would you use at the NetApp storage layer?

  • A. FlexArray
  • B. SnapVault
  • C. SnapMirror
  • D. MetroCluster

Answer: D

 

NEW QUESTION 25
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)

  • A. service profiles
  • B. blade servers
  • C. templates
  • D. boot from SAN

Answer: A,B

Explanation:
Cisco introduced the idea of stateless computing with its blade server design.
A Cisco UCS instance allows you to quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility is determined by whether you choose to fully implement the stateless computing feature.
Pools of servers and other system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no need for additional network configuration.

 

NEW QUESTION 26
A service provider is designing a FlexPod configuration to host multiple customers in a hybrid cloud environment, where IP address-range conflicts might arise on the shared storage.
Which NetApp feature should be enabled to prevent these conflicts?

  • A. SVMs
  • B. IPspaces
  • C. failover groups
  • D. broadcast domains

Answer: B

 

NEW QUESTION 27
Click the Exhibit button.

You have designed a FlexPod Express solution that uses a NetApp ONTAP controller, Cisco UCS C-Series servers, and Cisco Nexus 3000 Series switches, as shown in the exhibit. Which three storage protocols are supported in this design? (Choose three.)

  • A. FC
  • B. iSCSI
  • C. NFS
  • D. FCoE
  • E. SMB

Answer: A,B,C

 

NEW QUESTION 28
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?

  • A. 2204XP.
  • B. 0
  • C. 2208XP
  • D. 1

Answer: A

Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

 

NEW QUESTION 29
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. Cluster mode
  • B. Multipath mode
  • C. DualWire Management mode
  • D. Direct Connect mode
  • E. SingleConnect mode

Answer: C,D,E

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 30
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)

  • A. a two-node FAS8200 with a 4 TB NL-SAS HDD
  • B. a DS4246 with twenty-four 6 TB NL-SAS HDDs
  • C. a DS224C with twenty-four 3.8 TB SSDs
  • D. a two-node AFF A200 with a 3.8 TB NSE SSD

Answer: A,C

 

NEW QUESTION 31
You are a data center architect at a service provider. You need to configure a new multi-tenant FlexPod service offering.
Which three UCS Manager features will you need to accomplish this task? (Choose three.)

  • A. policies
  • B. virtualization support
  • C. service profiles
  • D. auto discovery
  • E. role-based access control

Answer: A,C,E

 

NEW QUESTION 32
You are configuring a FlexPod system for NAS protocols. You want to ensure that there are multiple paths between the initiators and targets in the solution.
Which two steps will accomplish this task? (Choose two.)

  • A. Configure the VSANs in the Cisco Nexus 5000 switches.
  • B. Configure the VLANs in Cisco UCS Manager as Common/Global.
  • C. Allow the VLANs over the vPC peer link.
  • D. Disable LACP.

Answer: B,D

 

NEW QUESTION 33
Your customer wants assurances that all aspects of FlexPod are highly available.
Which statement is correct in this scenario?

  • A. Cisco UCS Manager automatically copies its configuration data to a remote data store.
  • B. Cisco UCS Manager contains multiple UCS domains.
  • C. Cisco UCS Manager maintains a replica of configuration information.
  • D. Cisco UCS Manager uses active-active architecture.

Answer: C

Explanation:
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies.

 

NEW QUESTION 34
You are configuring Cisco UCS servers for FC SAN boot and want to perform zoning on your Cisco Nexus 5000 series switches.
In this scenario, which statement is correct?

  • A. An iSCSI license on the NetApp storage controller is required.
  • B. The corresponding FC ports on your NetApp storage array must be configured in LACP mode.
  • C. FC zoning on the Nexus series switches is not supported; zoning can be done only on the Cisco Fabric Interconnects.
  • D. SAN links are required between the Cisco Fabric Interconnects and the Nexus 5000 switches.

Answer: C

 

NEW QUESTION 35
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?

  • A. access mode
  • B. end host mode
  • C. trunk mode
  • D. switching mode

Answer: D

 

NEW QUESTION 36
......


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Virtualization Hypervisor Solutions, SAN Boot
Topic 2
  • Storage Hardware components, Configuration, High availability, SAN Boot
Topic 3
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager

 

NS0-173 Dumps PDF and Test Engine Exam Questions: https://www.realexamfree.com/NS0-173-real-exam-dumps.html