100% Free Microsoft Certified: Azure IoT Developer Specialty AZ-220 Dumps PDF Demo Cert Guide Cover
PDF Exam Material 2023 Realistic AZ-220 Dumps Questions
NEW QUESTION # 25
Your company is creating a new camera security system that will use Azure IoT Hub.
You plan to use an Azure IoT Edge device that will run Ubuntu Server 18.04.
You need to configure the IoT Edge device.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Explanation:
Step 1: Run the following commands
Install the container runtime.
Azure IoT Edge relies on an OCI-compatible container runtime. For production scenarios, we recommended that you use the Moby-based engine provided below. The Moby engine is the only container engine officially supported with Azure IoT Edge. Docker CE/EE container images are compatible with the Moby runtime.
Install the Moby engine.
sudo apt-get install moby-engine
Install the Moby command-line interface (CLI). The CLI is useful for development but optional for production deployments.
sudo apt-get install moby-cli
Install the security daemon. The package is installed at /etc/iotedge/.
sudo apt-get install iotedge
Step 2: From IotHub,create an IoT Edge device registry entry.
Note: In your IoT Hub in the Azure portal, IoT Edge devices are created and managed separately from IOT devices that are not edge enabled.
Sign in to the Azure portal and navigate to your IoT hub.
In the left pane, select IoT Edge from the menu.
Select Add an IoT Edge device.
Provide a descriptive device ID. Use the default settings to auto-generate authentication keys and connect the new device to your hub.
Select Save.
Retrieve the connection string in the Azure portal
1. When you're ready to set up your device, you need the connection string that links your physical device with its identity in the IoT hub.
2. From the IoT Edge page in the portal, click on the device ID from the list of IoT Edge devices.
3. Copy the value of either Primary Connection String or Secondary Connection String.
Step 3: Add the connection string to..
To manually provision a device, you need to provide it with a device connection string that you can create by registering a new device in your IoT hub.
Open the configuration file.
sudo nano /etc/iotedge/config.yaml
Find the provisioning configurations of the file and uncomment the Manual provisioning configuration section. Update the value of device_connection_string with the connection string from your IoT Edge device.
Save and close the file.
After entering the provisioning information in the configuration file, restart the daemon:
sudosystemctl restart iotedge
Reference:
https://docs.microsoft.com/en-us/azure/iot-edge/how-to-install-iot-edge-linux
NEW QUESTION # 26
You have three Azure IoT hubs named Hub1, Hub2, and Hub3, a Device Provisioning Service instance, and an IoT device named Device1.
Each IoT hub is deployed to a separate Azure region. Device enrollment uses the Lowest latency allocation policy.
The Device Provisioning Service uses the Lowest latency allocation policy. Device1 is auto-provisioned to Hub1 by using the Device Provisioning Service. Device1 regularly moves between regions.
You need to ensure that Device1 always connects to the IoT hub that has the lowest latency. What should you do?
- A. Disenroll and reenroll Device1.
- B. Implement device certificate rolling.
- C. Configure the re-provisioning policy.
- D. Configure device attestation that uses X.509 certificates.
Answer: C
Explanation:
Automated re-provisioning support.
Microsoft added first-class support for device re-provisioning which allows devices to be reassigned to a different IoT solution sometime after the initial solution assignment. Re-provisioning support is available in two options:
Factory reset, in which the device twin data for the new IoT hub is populated from the enrollment list instead of the old IoT hub. This is common for factory reset scenarios as well as leased device scenarios. Migration, in which device twin data is moved from the old IoT hub to the new IoT hub. This is common for scenarios in which a device is moving between geographies.
Reference:
https://azure.microsoft.com/en-us/blog/new-year-newly-available-iot-hub-device-provisioning-service-features/
NEW QUESTION # 27
You have an Azure IoT Central application.
You add an IoT device named Oven1 to the application. Oven1 uses an IoT Central template for industrial ovens.
You need to send an email to the managers group at your company as soon as the oven temperature falls below 400 degrees.
Which two actions should you perform? Each correct answer presents part of the solution.
NOTE: Each correct selection is worth one point.
- A. From IoT Central, create a telemetry rule for the template.
- B. Create a SendGrid account in the same resource group as the IoT Central application.
- C. Add the Manager role to the IoT Central application.
- D. Add a condition that has Aggregation set to Minimum.
- E. Add a condition that has Time Aggregation set to Off.
Answer: A,E
Explanation:
Devices use telemetry to send numerical data from the device. A rule triggers when the selected telemetry crosses a specified threshold.
E: To create a telemetry rule, the device template must include at least one telemetry value. The rule monitors the temperature reported by the device and sends an email when it falls below 400 degrees.
B: Configure the rule conditions.
Conditions define the criteria that the rule monitors. In this tutorial, you configure the rule to fire when the temperature exceeds 70° F.
1. Select Temperature in the Telemetry dropdown.
2. Next, choose Is less than as the Operator and enter 400 as the Value.
3. Optionally, you can set a Time aggregation. When you select a time aggregation, you must also select an aggregation type, such as average or sum from the aggregation drop-down.
Without aggregation, the rule triggers for each telemetry data point that meets the condition.
With aggregation, the rule triggers if the aggregate value of the telemetry data points in the time window meets the condition.
Reference:
https://docs.microsoft.com/en-us/azure/iot-central/core/tutorial-create-telemetry-rules
NEW QUESTION # 28
You need to visualize Azure IoT Hub telemetry data by using Microsoft Power BI.
Which service should you connect to the IoT hub?
- A. SendGrid
- B. Azure Event Grid
- C. Azure Stream Analytics
- D. Azure Notification Hubs
Answer: C
Explanation:
You can use Microsoft Power BI to visualize real-time sensor data that your Azure IoT hub receives. To do so, you configure an Azure Stream Analytics job to consume the data from IoT Hub and route it to a dataset in Power BI.
Reference:
https://docs.microsoft.com/en-us/azure/iot-hub/iot-hub-live-data-visualization-in-power-bi
NEW QUESTION # 29
You have an Azure IoT hub.
You plan to attach three types of IoT devices as shown in the following table.
You need to select the appropriate communication protocol for each device.
What should you select? To answer, drag the appropriate protocols to the correct devices. Each protocol may be used once, more than once, or not at all. You may need to drag the split bar between panes or scroll to view content.
NOTE: Each correct selection is worth one point.
Answer:
Explanation:
Reference:
https://docs.microsoft.com/en-us/azure/iot-hub/iot-hub-devguide-protocols
NEW QUESTION # 30
You have an Azure IoT hub and three Azure IoT Edge devices. The device twin code for each device is shown in the following table.
A standard automatic deployment is already applied.
You have three layered deployments. The deployment code for each deployment is shown in the following table.
For each of the following statements, select Yes if the statement is true. Otherwise select No. NOTE: Each correct selection is worth one point.
Answer:
Explanation:
NEW QUESTION # 31
You use Azure Security Center in an Azure IoT solution.
You need to exclude some security events. The solution must minimize development effort. What should you do?
- A. Add configuration details to the device twin object.
- B. Create an azureiotsecurity module twin and add configuration details to the module twin object.
- C. Create an Azure function to filter security messages.
- D. Add a configuration to the code of the physical IoT device.
Answer: B
Explanation:
Properties related to every Azure Security Center for IoT security agent are located in the agent configuration object, within the desired properties section, of the azureiotsecurity module.
To modify the configuration, create and modify this object inside the azureiotsecurity module twin identity. Note: Azure Security Center for IoT's security agent twin configuration object is a JSON format object. The configuration object is a set of controllable properties that you can define to control the behavior of the agent.
These configurations help you customize the agent for each scenario required. For example, automatically excluding some events, or keeping power consumption to a minimal level are possible by configuring these properties.
Reference:
https://docs.microsoft.com/en-us/azure/asc-for-iot/how-to-agent-configuration
NEW QUESTION # 32
You need to install the Azure IoT Edge runtime on a new device that runs Windows 10 IoT Enterprise.
Which four actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Explanation
Step 1: From Azure IoT Hub, create an IoT Edge Device
Step 2: Deploy-IoTEdge
The Deploy-IoTEdge command checks that your Windows machine is on a supported version, turns on the containers feature, and then downloads the moby runtime and the IoT Edge runtime. The command defaults to using Windows containers.
{Invoke-WebRequest -useb https://aka.ms/iotedge-win} | Invoke-Expression; ` Deploy-IoTEdge Step 3: Initialize-IoTEdge The Initialize-IoTEdge command configures the IoT Edge runtime on your machine. The command defaults to manual provisioning with Windows containers.
{Invoke-WebRequest -useb https://aka.ms/iotedge
Step 4: Enter the IoT Edge device connection string.
When prompted, provide the device connection string that you retrieved in step 1. The device connection string associates the physical device with a device ID in IoT Hub.
Reference:
https://docs.microsoft.com/en-us/azure/iot-edge/module-composition
NEW QUESTION # 33
You have 20 devices that connect to an Azure IoT hub.
You open Azure Monitor as shown in the exhibit.
You discover that telemetry is not being received from five IoT devices.
You need to identify the names of the devices that are not generating telemetry and visualize the data.
What should you do first?
- A. Add the Number of throttling errors metric and archive the logs to an Azure storage account.
- B. Configure diagnostics for Connections and send the logs to Azure Log Analytics.
- C. Add the Telemetry messages sent metric and archive the logs to an Azure Storage account.
- D. Configure diagnostics for Routes and stream the logs to Azure Event Hubs.
Answer: B
Explanation:
To log device connection events and errors, turn on diagnostics for IoT Hub. We recommend turning on these logs as early as possible, because if diagnostic logs aren't enabled, when device disconnects occur, you won't have any information to troubleshoot the problem with.
1. Sign in to the Azure portal.
2. Browse to your IoT hub.
3. Select Diagnostics settings.
4. Select Turn on diagnostics.
5. Enable Connections logs to be collected.
6. For easier analysis, turn on Send to Log Analytics

Reference:
https://docs.microsoft.com/bs-cyrl-ba/azure/Iot-hub/iot-hub-troubleshoot-connectivity
NEW QUESTION # 34
You have 10 devices that connect to an Azure loT hub. Each device has a unique public IP address. The devices are not provisioned through DPS.
You discover an anomaly in messages from two devices.
You need to stop all messages from both devices without affecting the other devices.
Solution: You create a custom endpoint for the loT hub and configure a message routing query to redirect events from suspicious devices.
Does this meet the goal?
- A. No
- B. Yes
Answer: A
NEW QUESTION # 35
You have an Azure IoT solution that includes an Azure IoT hub.
You plan to deploy 10,000 IoT devices.
You need to validate the performance of the IoT solution while 10,000 concurrently connected devices stream telemetry. The solution must minimize effort.
What should you deploy?
- A. an Azure IoT Edge gateway configured as a protocol translation gateway
- B. an Azure function, an IoT Hub device SDK, and a timer trigger
- C. an Azure IoT Device Simulation from Azure IoT Solution Accelerator
- D. Azure IoT Central application and a template for the retail industry
Answer: C
Explanation:
The IoT solution accelerators are complete, ready-to-deploy IoT solutions that implement common IoT scenarios. The scenarios include connected factory and device simulation.
Use the Device Simulation solution accelerator to run simulated devices that generate realistic telemetry. You can use this solution accelerator to test the behavior of the other solution accelerators or to test your own custom IoT solutions.
Reference:
https://docs.microsoft.com/en-us/azure/iot-accelerators/about-iot-accelerators
Topic 1, ADatum
Requirements
Planned Changes
ADatum is developing an Azure IoT solution to monitor environmental conditions. The IoT solution consists of hardware devices and cloud services. All the devices will communicate directly to Azure IoT Hub.
The hardware devices will be deployed to the branch offices and will collect data about various environmental conditions such as temperature, humidity, air quality, and noise level. The devices will be wired by using Power over Ethernet (PoE) connections.
ADatum is developing the solution in the following three phases: proof of value (POV), pilot, and production.
Requirements. POV Requirements
The POV phase will demonstrate that a technical solution is viable. During this phase, 100 devices will be deployed to the main office and Azure Stream Analytics will be connected to an IoT hub to generate real-time alerts. Stream Analytics will perform the following processing:
Calculate the median rate of the telemetry across the entire devices that exceed the median rate by a factor of 4.
Compare the current telemetry to the specified thresholds and issue alerts when telemetry values are out of range.
Ensure that all message content during this phase is human readable to simplify debugging.
Requirements. Pilot Requirements
During the pilot phase, devices will be deployed to 10 offices. Each office will have up to 1,000 devices.
During this phase, you will add Azure Time Series Insights in parallel to Stream Analytics to support real-time graphs and queries in a dashboard web app.
The pilot deployment must minimize operating costs.
Requirements. Production Requirements
The production phase will include all the offices.
The production deployment will have one IoT hub in each Azure region. Devices must connect to the IoT hub in their region.
The production phase must meet the following requirements:
Ensure that the IoT solution can support performance and scale targets.
Ensure that the IoT solution support up to 1,000 devices per office.
Minimize operating costs of the IoT solution.
Requirements. Technical Requirements
Datum identifies the following requirements for the planned IoT solution:
The solution must generate real-time alerts when a fire condition is detected in an office. All the devices in that office must trigger an audible alarm siren within 10 seconds of the alert.
A dashboard UI must display alerts and the system status in real time and must allow device operators to make adjustments to the system.
Each device will send hourly updates to IoT Hub. Condition alerts will be sent immediately.
Multiple types of devices will collect telemetry that has different schemas.
IoT Hub must perform message routing based on the message body.
Direct methods must be used for cloud-to-device communication.
Reports must be provided monthly, quarterly, and annually.
Stored data queries must be as efficient as possible.
The device message size will be under 4 KB.
Development effort must be minimized.
Requirements. Throttle and Quotas
The relevant throttles and quotas for various IoT Hub tiers are shown in the following table.
Requirements. IoT Hub Routing
You plan to implement IoT Hub routing during the POV phase as shown in the following exhibit.
NEW QUESTION # 36
You have 1,000 devices that connect to an Azure IoT hub.
You are performing a scheduled check of deployed IoT devices. You plan to run the following command from the Azure CLI prompt.
az iot hub query --hub-name hub1 --query-command "SELECT * FROM devices WHERE connectionState =
'Disconnected'"
What does the command return?
- A. the device twins
- B. the Connections logs
- C. the device credentials
- D. the Device Disconnected events
Answer: D
Explanation:
Explanation
The IoT Hub publishes the Microsoft.Devices.DeviceDisconnected event type, which is published when a device is disconnected from an IoT hub.
Reference:
https://docs.microsoft.com/en-us/azure/iot-hub/iot-hub-event-grid#event-types
NEW QUESTION # 37
You need to add Time Series Insights to the solution to meet the pilot requirements.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Explanation
Step 1: Provision Time Series Insights
Select Provision new IoT Hub to create a new IoT hub.
Step 2: Route telemetry from IoT Hub to a custom event.
Step 3: Add a data access policy to Time Series Insights for the dashboard web app Scenario: Requirements. Pilot Requirements During the pilot phase, devices will be deployed to 10 offices. Each office will have up to 1,000 devices.
During this phase, you will add Azure Time Series Insights in parallel to Stream Analytics to support real-time graphs and queries in a dashboard web app.
The pilot deployment must minimize operating costs.
Reference:
https://docs.microsoft.com/en-us/azure/time-series-insights/time-series-insights-update-create-environment
NEW QUESTION # 38
You create an Azure Stream Analytics job that has the following query.
The job is configured to have an Azure IoT Hub input and an output to an Azure function.
For each of the following statements, select Yes if the statement is true. Otherwise, select No.
NOTE: Each correct selection is worth one point.
Answer:
Explanation:
Reference:
https://docs.microsoft.com/en-us/stream-analytics-query/time-management-azure-stream-analytics
NEW QUESTION # 39
Note: This question is part of a series of questions that present the same scenario. Each question in the series contains a unique solution that might meet the stated goals. Some question sets might have more than one correct solution, while others might not have a correct solution.
After you answer a question in this question, you will NOT be able to return to it. As a result, these questions will not appear in the review screen.
You have an Azure IoT solution that includes an Azure IoT hub, a Device Provisioning Service instance, and
1,000 connected IoT devices.
All the IoT devices are provisioned automatically by using one enrollment group.
You need to temporarily disable the IoT devices from the connecting to the IoT hub.
Solution: From the Device Provisioning Service, you disable the enrollment group, and you disable device entries in the identity registry of the IoT hub to which the IoT devices are provisioned.
Does the solution meet the goal?
- A. Yes
- B. No
Answer: A
Explanation:
You may find it necessary to deprovision devices that were previously auto-provisioned through the Device Provisioning Service.
In general, deprovisioning a device involves two steps:
1. Disenroll the device from your provisioning service, to prevent future auto-provisioning. Depending on whether you want to revoke access temporarily or permanently, you may want to either disable or delete an enrollment entry.
2. Deregister the device from your IoT Hub, to prevent future communications and data transfer. Again, you can temporarily disable or permanently delete the device's entry in the identity registry for the IoT Hub where it was provisioned.
Reference:
https://docs.microsoft.com/bs-latn-ba/azure/iot-dps/how-to-unprovision-devices
AZ-220
Number: AZ-220
Passing Score: 800
Time Limit: 120 min
File Version: 1
AZ-220
Implement the IoT solution infrastructure
Testlet 1
Case Study
This is a case study. Case studies are not timed separately. You can use as much exam time as you
would like to complete each case. However, there may be additional case studies and sections on this
exam. You must manage your time to ensure that you are able to complete all questions included on this exam
in the time provided.
To answer the questions included in a case study, you will need to reference information that is provided in the
case study. Case studies might contain exhibits and other resources that provide more information about the
scenario that is described in the case study. Each question is independent of the other question on this case
study.
At the end of this case study, a review screen will appear. This screen allows you to review your answers and
to make changes before you move to the next sections of the exam. After you begin a new section, you cannot
return to this section.
To start the case study
To display the first question on this case study, click the Next button. Use the buttons in the left pane to explore
the content of the case study before you answer the questions. Clicking these buttons displays information
such as business requirements, existing environment, and problem statements. If the case study has an All
Information tab, note that the information displayed is identical to the information displayed on the subsequent
tabs. When you are ready to answer a question, click the Question button to return to the question.
Existing Environment. Current State of Development
Contoso produces a set of Bluetooth sensors that read the temperature and humidity. The sensors connect to
IoT gateway devices that relay the data.
All the IoT gateway devices connect to an Azure IoT hub named iothub1.
Existing Environment. Device Twin
You plan to implement device twins by using the following JSON sample.
Existing Environment. Azure Stream Analytics
Each room will have between three to five sensors that will generate readings that are sent to a single IoT
gateway device. The IoT gateway device will forward all the readings to iothub1 at intervals of between 10 and
60 seconds.
You plan to use a gateway pattern so that each IoT gateway device will have its own IoT Hub device identity.
You draft the following query, which is missing the GROUP BYclause.
SELECT
AVG(temperature),
System.TimeStamp() AS AsaTime
FROM
Iothub
You plan to use a 30-second period to calculate the average temperature reading of the sensors.
You plan to minimize latency between the condition reported by the sensors and the corresponding alert issued
by the Stream Analytics job.
Existing Environment. Device Messages
The IoT gateway devices will send messages that contain the following JSON data whenever the temperature
exceeds a specified threshold.
The levelproperty will be used to route the messages to an Azure Service Bus queue endpoint named
criticalep.
Existing Environment. Issues
You discover connectivity issues between the IoT gateway devices and iothub1, which cause IoT devices to
lose connectivity and messages.
Requirements. Planning Changes
Contoso plans to make the following changes:
* Use Stream Analytics to process and view data.
* Use Azure Time Series Insights to visualize data.
* Implement a system to sync device statuses and required settings.
* Add extra information to messages by using message enrichment.
* Create a notification system to send an alert if a condition exceeds a specified threshold.
* Implement a system to identify what causes the intermittent connection issues and lost messages.
Requirements. Technical Requirements
Contoso must meet the following requirements:
* Use the built-in functions of IoT Hub whenever possible.
* Minimize hardware and software costs whenever possible.
* Minimize administrative effort to provision devices at scale.
* Implement a system to trace message flow to and from iothub1.
* Minimize the amount of custom coding required to implement the planned changes.
* Prevent read operations from being negatively affected when you implement additional services.
Implement the IoT solution infrastructure
Question Set 2
NEW QUESTION # 40
......
Updated Microsoft AZ-220 Dumps – PDF & Online Engine: https://www.realexamfree.com/AZ-220-real-exam-dumps.html
AZ-220.pdf - Questions Answers PDF Sample Questions Reliable: https://drive.google.com/open?id=1MDgf4-mkfmpAxNnUnteQtK_Bd0VSKyWw

